UTC BT138 TRIACS LOGIC LEVEL DESCRIPTION Passivated triacs in a plastic envelope, intended for use in applications requiring high bidirectional transient and blocking voltage capability and high thermal cycling performance. Typical applications include motor control, industrial and domestic lighting, heating voltages and static switching. 1 TRIAC SYMBOL MT2 TO-220 G MT1 1:MT1 2:MT2 3:GATE ABSOLUTE MAXIMUM RATINGS ( Tj=25C) PARAMETER Repetitive Peak Off State Voltage BT138-600 BT138-800 RMS On-state Current (Full sine wave; Tmb99C) Non-repetitive Peak. On-State Current (Full sine wave; Tj=25C prior to surge) t=20ms t=16.7ms SYMBOL VDRM RATING 600 800 12 UNIT V A A IT(RMS) ITSM I2t For Fusing (t=10ms) I2t A2s Repetitive Rate of Rise of On-state Current after Triggering dIT/dt (ITM=20A;IG=0.2A; dIG/dt=0.2A/s) 50 T2+G+ A/s 50 T2+G50 T2-G10 T2-G+ Peak Gate Voltage VGM 5 V Peak Gate Current IGM 2 A Peak Gate Power PGM 5 W Average Gate Power PG(AV) 0.5 W Operating Junction Temperature Tj 125 C Storage Temperature Tstg -40~150 C *Although not recommended, off-state voltages up to 800V may be applied without damage, but the triac may switch to the on-state. The rate of rise of current should not exceed 15A/s. 95 105 45 UTC UNISONIC TECHNOLOGIES CO., LTD. 1 QW-R401-002,A UTC BT138 THERMAL RESISTANCES PARAMETER Thermal Resistance, Junction to Mounting Base Full cycle Half cycle Thermal Resistance, Junciton to Ambient In free air TRIAC SYMBOL Rj-mb Rj-a 60 MIN TYP MAX 1.5 2.0 - UNIT C /W C /W STATIC CHARACTERISTICS (Tj=25C,unless otherwise specified) PARAMETER Gate Trigger Current T2+G+ T2+GT2-GT2-G+ Latching Current T2+G+ T2+GT2-GT2-G+ Holding Current On-State Voltage Gate Trigger Voltage Off-state Leakage Current IL IGT SYMBOL TEST CONDITIONS VD=12V, IT=0.1A MIN TYP 5 8 10 12 MAX 35 35 35 70 40 60 40 60 30 1.65 1.5 0.5 UNIT mA VD=12V, IGT =0.1A 7 20 8 10 6 1.4 0.25 0.7 0.4 0.1 mA IH VT VGT ID VD=12V, IGT=0.1A IT=15A VD=12V, IT=0.1A VD=400V, IT=0.1A, Tj=125C VD=VDRM(max) , Tj=125C mA V V mA DYNAMIC CHARACTERISTICS (Tj=25C,unless otherwise specified) PARAMETER Critical Rate Of Rise Of Off-State Voltage Critical Rate Of Change Of Commutating Voltage Gate Controlled Turn-on Time SYMBOL dVD/dt TEST CONDITIONS VDM=67% VDRM(max), Tj=125C Exponential waveform, Gate open circuit VDM=400V,Tj=95C, IT(RMS)=12A dlcom/dt =5.4A/ms, Gate open circuit ITM=16A, VD=VDRM(max), IG=0.1A dIG/dt=5A/s MIN 100 TYP MAX 250 UNIT V/s 20 V/s dVcom/dt tgt 2 s UTC UNISONIC TECHNOLOGIES CO., LTD. 2 QW-R401-002,A UTC BT138 TYPICAL CHARACTERISTICS Figure 1.Maximum on -state Dissipation.Ptot vs RMS On-state Current,IT(RMS),W here=conduction Angle. 20 Ptot/W T mb(max)/C 95 15 TRIAC Figure 4.Maximum Permissible RMS Current IT(RMS) vs mounting baseT emperature T m b IT (RMS)/A =180 15 =120 102.5 =90 =60 =30 110 99 10 10 5 5 117.5 0 0 5 IT (RMS)/A 10 125 15 0 -50 0 50 T mb/ 100 150 1000 Figure 2. Maximum Permissible Non-repetitive Peak O n-state Current ITSM,vs Pulse W idth tp,for Sinusoidal Currents,tp20ms IT SM/A 25 20 15 Figure 5.Maximum Permissible Repetitive RMS on-state Current IT (RMS),vs Surge Duration,for Sinusoidal C urrents,f=50Hz;T mb99 IT (RMS)/A 100 dIT/dt limit T 2-G + quadrant 10 10us 100us 1ms T /s IT T Tj initial= 25m ax ITSM time 10 5 0 0.01 10ms 100ms 0.1 1 Surge Duration /S 10 100 80 Figure 3 .Maximum Permissible Non-Repetitive peak on-state Current ITSM,vs Number of Cycles, for Sinusoidal Currents,f=50Hz IT SM/A IT ITSM time T Tj initial=25m ax VGT(T j) 1.6 1.4 1.2 1 Figure 6.Normalised G ate T rigger Voltage VGT(T j)/ VGT(25),vs Junction T emperature T j VGT(25) 60 40 20 0 0.8 0.6 0.4 -50 0 50 T j/ 100 150 1 100 10 Number of Cycles at 50Hz 1000 UTC UNISONIC TECHNOLOGIES CO., LTD. 3 QW-R401-002,A UTC BT138 Figure 7.Normalised Gate T rigger Current IGT(T j)/IGT(25),vs Junction T emperature Tj IGT(T j) IGT(25) T 2+G+ T 2+G T 2-GT 1-G + Figure 10.Typical and Maximum O n-state Characteristic 40 IT/A Tj=125 30 Tj=25 Vo=1.75V Rs=0.316Ohms 20 typ TRIAC 3 2.5 2 1.5 1 max 10 0.5 0 -50 0 50 T j/ 100 150 0 0 0.5 1 1.5 VT /V 2 2.5 3 IL(T j) 3 2.5 2 1.5 1 IL(25) Figure 8.Normalised Latching Current IL(T j)/IL(25),vs Junction T emperature T j 10 Figure 11.Transient Thermal Impedance Zth j-mb,vs Pulse W idth tp Zth j-mb (K/W ) 1 unidirectional bidirectional 0.1 0.01 0.5 0 -50 0 50 T j/ Figure 9.Normalised Holding Current IH(T j)/IH(25),vs Junction T emperature Tj IH(T j) 3 2.5 2 1.5 1 0.5 0 -50 0 1 50 T j/ 100 150 0 50 Tj/ 10 100 IH(25) 100 150 0.001 10us 0.1ms 1ms 10ms tp/s PD tp t 0.1s 1s 10s Figure 12.T ypical commutation dV/dt vs junction temperature,parameter commutation dlT/dt.The triac should commutate when the dV/dt is below the value on the appropriate curve for pre-commutation dlT/dt dV/dt(V/us) 1000 dIcom/dt=5.4A/ms 100 150 UTC UNISONIC TECHNOLOGIES CO., LTD. 4 QW-R401-002,A UTC BT138 TRIAC UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. UTC UNISONIC TECHNOLOGIES CO., LTD. 5 QW-R401-002,A |
Price & Availability of BT138 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |